Engineered Chemical Earthing & Lightning Protection Systems

CPRI Tested & IS 3043 Compliant Grounding Solutions Engineered for Solar Parks, Industrial Plants, and Critical Electrical Infrastructure.

FROM GROUND TO GLOW
Electrohaat bring for you
Pipe-in-Pipe & Flat-in-Pipe Technology Tested for Heavy Fault-Current Dissipation

Copper Bonded Electrodes

Pipe-in-Pipe / Flat-in-Pipe Technology
  • 99% uniform copper coating for extended service life
  • RDSO Compliant: RDSO/PE/SPEC/PS/0109-2008
  • Suitable for soil pH 5.0 to 8.0

Galvanized Iron (GI) Electrodes

Heavy-Duty Hot-Dip Galvanized
  • Hot-dip galvanized coating to prevent subterranean corrosion
  • Outer Diameters: 48–50 mm & 76–80 mm | Lengths: 1m, 2m, 3m
  • Terminal Holes: 10mm & 12mm dual-hole connections

Copper Bonded Grounding Rods

High-Tensile Steel Core
  • Diameters: 12 mm, 14.2 mm, 17.2 mm, 23.2 mm
  • Molecular copper plating thickness: 254 to 330 Microns
  • Thread sizes: 9/16″, 5/8″, 3/4″, 1″ UNC

Earth Enhancing Backfill Compound

IEC 62561-7 Certified Environmental Standard
  • Absorbs moisture up to 20x dry volume and retains hydration
  • Tested for Leaching, Corrosion, Sulfur, and Low Resistivity
  • Replaces salt and charcoal; harmless to soil and local water tables

Why Choose Chemical Earthing?

Chemical Advanced Grounding vs. Traditional Salt & Charcoal Systems
ParameterAdvanced Chemical EarthingTraditional Plate / Pipe Earthing
TechnologyAdvanced Pipe-in-Pipe / Flat-in-Pipe designSingle strip with GI/Copper plate
Space RequiredCompact; requires only an 8 to 10-inch boreNeeds large 2 ft X 2 ft excavation pit
MaintenanceMaintenance-free; no periodic watering requiredHigh maintenance; requires regular watering every 3 months
TestingStable ohmic value; no frequent testing neededUnstable resistance; regular testing mandatory
Corrosion RateMinimal corrosion; uniform molecular bondingRapid corrosion due to salt and chemical erosion
Expected LifespanLong service life (10 to 15+ years)Deteriorates in less than 10 years
Total CostHighly cost-effective over lifecycleCostly recurring maintenance & replacement

Standard Installation Process

Recommended Procedure for Chemical Gel Earthing Electrode Installation

Soil Assessment & Pit Boring

Electrode Placement

Backfill Compound Application

Terminal Joint Connection

Chamber & Corrosion Protection

Initial Curing

– Testimonial Author Name

– Testimonial Author Name

– Testimonial Author Name

Request a Technical Project Quote

Connect with Our Engineering Team for Soil Assessment, Bulk Inquiries & Dispatch

Instant Direct Contact & Support

Connect Now | Monday to Saturday | Time ; 9:00 AM to 6:30 PM